當前位置:昆山瑞騰精密自動化有限公司>>東京計器TOKYO KEIKI>>TOKYOKEIKI疊加閥>> TGMC-3-PT-FW-50-S16東京計器溢流疊加閥TGMC-3-PT-FW-50
東京計器TOKYOKEIKI疊加閥TGMC-5-PT-Gh-50
東京計器TOKYOKEIKI疊加閥TGMC-5-PT-Gw-50
東京計器溢流疊加閥TGMC2-3-AT-GW-BT-BW_50
| 應用領域 | 綜合 | Max.工作壓力 | 31.5MPa |
|---|
TGMC-3-PT-Fw-50 TOKYO KEIKI 東京計器溢流疊加閥TGMC-3-PT-FW-50
品牌:TOKYO KEIKI 東京計器 (原舊稱TOKIMEC)
型號:TGMC-3-PT-FW-50
Max.使用壓力:31.5 MPa
Max.流量:60 L/min
產地:日本
TGMC-3-PT-Fw-50 TOKYO KEIKI 東京計器溢流疊加閥TGMC-3-PT-FW-50是液壓系統中常用的壓力控制元件,其核心特點是采用疊加式安裝結構,適配集成化液壓系統,具體特點如下:安裝便捷,結構緊湊、管路簡化,減少泄漏。
疊加型溢流閥 TGMC(2)-3,50 系列 Pressure relief modules
型號
(F3)-TGMC(2)-3-** (L)-*W(- B*-*W)-50
1 2 3 4 5 6 7 8 9 10 11
1 適用液壓油無記號:石油類液壓油、水?乙二醇類液壓油F3:磷酸脂類液壓油
2 溢流功能的種類TGMC:單溢流閥TGMC2:雙溢流閥3 安裝面尺寸
3:ISO 4401-03
4 控制油路PT:P → T 溢流(限用于單溢流閥)AT:A → T 溢流BT:B → T 溢流(限用于單溢流閥)AB:A → B 溢流BA:B → A 溢流(限用單溢流閥)
5 調節部的位置 :詳細說明請參照[外形尺寸]
6 壓力調節范圍A:(0.3)~ 5 MPaB:(0.3)~ 10 MPaF:(1)~ 20 MPaG:(5)~ 31.5 MPa(Min.壓力因流量的不同而有差異。請參照特性曲線圖。)
7 調節部形狀W:內六角調節螺釘型H:旋鈕型
8 控制油路(適用于 TGMC2 型)BT:B → T 溢流(限用于雙溢流閥)BA:B → A 溢流(限于雙溢流閥)
9 壓力調節范圍參照6項 (適用于 TGMC2 型)
10 調節部形狀參照7項 (適用于 TGMC2 型)
11 設計編號
TGMC-3-PT-Fw-50 TOKYO KEIKI 東京計器溢流疊加閥TGMC-3-PT-FW-50是液壓系統中常用的壓力控制元件,其核心特點是采用疊加式安裝結構,適配集成化液壓系統,具體特點如下:
TGMC-3-PT-FW-50 TOKYO KEIKI Stack Pressure Relief Valve
Brand: TOKYO KEIKI (formerly TOKIMEC)
Model: TGMC-3-PT-FW-50
Max. operating pressure: 31.5 MPa
Max. flow rate: 60 L/min
Origin: Japan
TGMC-3-PT-FW-50 is a commonly used pressure control component in hydraulic systems. Its key feature is the stack-mounted design, suitable for integrated hydraulic systems, with the following advantages:
easy installation, compact structure, simplified piping, and reduced leakage.
Stack Pressure Relief Valves TGMC(2)-3, 50 Series
Model Designation
(F3)-TGMC(2)-3-**(L)-W(-B-*W)-50
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
Applicable hydraulic fluid
No marking: Petroleum-based hydraulic oil, water-glycol hydraulic oil
F3: Phosphate ester hydraulic oil
Relief function type
TGMC: Single relief valve
TGMC2: Double relief valve
Mounting surface size
3: ISO 4401-03
Control circuit
PT: P → T relief (single relief valve only)
AT: A → T relief
BT: B → T relief (single relief valve only)
AB: A → B relief
BA: B → A relief (single relief valve only)
Adjuster position
For details, refer to the outline dimension drawing.
Pressure adjustment range
A: (0.3) ~ 5 MPa
B: (0.3) ~ 10 MPa
F: (1) ~ 20 MPa
G: (5) ~ 31.5 MPa
Minimum pressure varies with flow rate; refer to the characteristic curve.
Adjuster type
W: Hex socket adjustment screw type
H: Knob type
Control circuit (for TGMC2 only)
BT: B → T relief (double relief valve only)
BA: B → A relief (double relief valve only)
Pressure adjustment range (for TGMC2 only)
Refer to item 6
Adjuster type (for TGMC2 only)
Refer to item 7
Design number
Product Features
TGMC-3-PT-FW-50 is a widely used pressure control component in hydraulic systems, featuring a stack-mounted structure ideal for integrated hydraulic systems.
Easy installation & compact structure
Stack-type relief valves require no additional connection blocks or piping. They can be directly stacked between hydraulic manifolds, actuators, or other stack valves and secured with bolts. This design greatly reduces the number of pipe joints, saves installation space, and is especially suitable for compact, integrated hydraulic systems.
Simplified piping & reduced leakage
Unlike conventional plate-type relief valves with long external lines and multiple leakage points, stack valves connect directly to adjacent components through internal oil passages. This eliminates external tubing, effectively lowering the risk of hydraulic oil leakage, while also reducing pressure loss and vibration noise.
Flexible configuration & high expandability
This relief valve can be freely combined and stacked with other stack-type valves of the same size (directional valves, throttle valves, check valves, etc.) to build hydraulic circuits as needed. System functions can be modified by adding, removing, or replacing stack valves without changing the main piping layout, resulting in low maintenance and retrofit costs.
Standardized size & good interchangeability
Stack valves follow standardized nominal sizes (such as NG6, NG10). Products of the same size from different brands are interchangeable, improving system versatility and spare parts management.
Stable pressure control & fast response
Based on the same working principle as conventional plate-type valves, it controls system pressure by balancing spring force and hydraulic pressure. It delivers stable pressure, high adjustment accuracy, and fast response, effectively protecting the system from overload.
Pressure loss characteristics
Since oil passages are integrated inside the valve body, pressure loss may be slightly higher under large-flow conditions compared to pipe or plate valves. Therefore, it is more suitable for small-to-medium flow hydraulic systems.
TGMC-3-PT-FW-50 TOKYO KEIKI Stack Pressure Relief Valve
請輸入賬號
請輸入密碼
請輸驗證碼
以上信息由企業自行提供,信息內容的真實性、準確性和合法性由相關企業負責,化工儀器網對此不承擔任何保證責任。